Discover how Qube Technologies supports businesses to reduce emissions and create new opportunities.
Case Studies
Rapid Methane Leak Detection at a Wellsite Separator
Real-time alerts and source localization caught a high-volume separator leak that would otherwise have gone unnoticed over a weekend, and it was repaired within the week.
How Qube’s Automated Alarms Caught a Cow at the Wellsite
A methane alert at a Colorado wellsite traced back to a cow that bumped open a valve. Crews shut it in and fenced the area to prevent it happening again.
How Qube’s Continuous Monitoring Found Leaking Level Controllers After Well Restart
A Colorado well pad restart triggered a large methane release, traced to leaking level controllers and thief hatches and repaired within a day.
How Qube Helped One Permian Operator Detect Offsite Emissions
A methane spike at a Permian site turned out to come from a neighboring gas plant, saving the operator an unnecessary inspection.
QB Energy and Qube Technologies Resolve Thief Hatch Leak Leading to 97% Emissions Reduction
An alert at a QB Energy tank site led crews to a leaking thief hatch that a visual inspection had missed. Resealing it cut emissions by 97 percent.
Methane Emissions Management Success Story: Birch Resources + Qube Technologies
Birch Resources used continuous monitoring to respond immediately to an unexpected flare outage, even as satellite surveys were still catching up.
Qube’s Continuous Emissions Monitoring Detects a Produced Water Spill in Real-Time
A methane alert that looked routine turned out to be a produced water spill from a failed manifold, caught and contained before it spread.
Rapid Leak Detection Prevented Potential Revenue Loss of $200,000 at Biogas Site
A midnight tear in a biogas lagoon was caught and fixed the next day, saving Roeslein Alternative Energy an estimated $200,000 in lost product.
Qube's Continuous Monitoring Verifies 60% Reduction in Methane Emissions from Pneumatic Device Upgrades
A methane alert that looked routine turned out to be a produced water spill from a failed manifold, caught and contained before it spread.
Diagnosing Excessive Emissions From Faulty Valves at a Permian Central Tank Battery: 63% Emission Reduction
A sudden emissions jump at a Permian tank battery was traced to faulty valves under high line pressure. Fixing them cut emissions by 63 percent.
Rapid Detection of Fugitive Leak from Stuck Thief Hatch at Well Pad
Monitoring at a Canadian well pad flagged above-baseline methane at the tank area, leading crews straight to a leaking thief hatch.
Optimizing Process Heater Efficiency Through Continuous Emissions Monitoring in British Columbia
A British Columbia facility tracked down excess process heater emissions, cutting monthly methane by 76 percent and carbon monoxide to zero.
Qube Outperforms the Competition: Fugitive Emissions from Thief Hatch Identified by Qube, Missed by Other Emissions Monitoring Technologies
At an Oklahoma well battery, monitoring caught a leak other technologies missed entirely. An open thief hatch was found and fixed, cutting emissions by 95 percent.
Optimizing Flare Function: Qube's Methane Sensors Detect and Localize a Fouled Flame Arrestor
Methane sensors in a British Columbia pilot traced rising flare emissions to a fouled flame arrestor, which once repaired dropped emissions by 75 percent.
Reducing Emissions with Qube's CO Sensors: A Compressor Efficiency Success Story
CO and methane sensors traced elevated readings to incomplete combustion in a compressor, cutting methane by 30 percent after tuning.
Qube Detects CH₄ and H₂S Leaks from Third Party Compressor at Alberta Gas Processing Facility
Monitoring at an Alberta gas plant caught dangerous methane and hydrogen sulfide leaks from new third-party compressor equipment early.