Diagnosing Excessive Emissions From Faulty Valves at a Permian Central Tank Battery: 63% Emission Reduction
A sudden emissions jump at a Permian tank battery was traced to faulty valves under high line pressure. Fixing them cut emissions by 63 percent.
Rapid Detection of Fugitive Leak from Stuck Thief Hatch at Well Pad
Monitoring at a Canadian well pad flagged above-baseline methane at the tank area, leading crews straight to a leaking thief hatch.
Optimizing Process Heater Efficiency Through Continuous Emissions Monitoring in British Columbia
A British Columbia facility tracked down excess process heater emissions, cutting monthly methane by 76 percent and carbon monoxide to zero.
Qube Outperforms the Competition: Fugitive Emissions from Thief Hatch Identified by Qube, Missed by Other Emissions Monitoring Technologies
At an Oklahoma well battery, monitoring caught a leak other technologies missed entirely. An open thief hatch was found and fixed, cutting emissions by 95 percent.
Optimizing Flare Function: Qube's Methane Sensors Detect and Localize a Fouled Flame Arrestor
Methane sensors in a British Columbia pilot traced rising flare emissions to a fouled flame arrestor, which once repaired dropped emissions by 75 percent.
Reducing Emissions with Qube's CO Sensors: A Compressor Efficiency Success Story
CO and methane sensors traced elevated readings to incomplete combustion in a compressor, cutting methane by 30 percent after tuning.
Qube Detects CH₄ and H₂S Leaks from Third Party Compressor at Alberta Gas Processing Facility
Monitoring at an Alberta gas plant caught dangerous methane and hydrogen sulfide leaks from new third-party compressor equipment early.